Contrôle de l'efficacité du filtre Breveté Ai

Test-Report No.: 2561702-1 Date: 20-09-2017 ImpulsePeak Insertion loss (IPIL) (Partial test) Page2of 6 _______________________________________________________________________________________ II. Client: Auditech Innovations Lebacher Str. 4 D-66113Saarbrücken Deutschland Contact Person: EnnoBurkhart Tel.-Nr.: +49 (0) 6819963714 E-Mail: enno.burghart@auditech-innovations.com WEB: www.auditech-innovations.com III. AccreditedLaboratory PZTGmbH Ander Junkerei 48F 26389Wilhelmshaven Germany Tel.-No.: +49 (0) 4421 / 70340 Fax-No.: +49 (0) 4421 / 70421 E-Mail: office@pzt-lab.de Accredit byDAkksCertificateNo. D-PL-12127-01-01 NotifiedBody: EU-IdentificationNumber: 1974 Reference: Ge / gg Third-party laboratory: -- IV. TestingStandards: ANSI/ASAS12.42-2010 Methods for theMeasurement of InsertionLoss of HearingProtectionDevices inContinuous or Impulsive NoiseUsingMicrophone-in-Real-Ear or Acoustic Test FixtureProcedures V. Conformance test conductedon: 2017-06-17 to 2017-07-10 VI. Measurement equipment Themeasurementswere conducted at measurement stationNo. 4 Themeasuring equipment is calibrated regularly; themeasuring devices are maintained regularly.

RkJQdWJsaXNoZXIy NzMwMTQ=